San Francisco Retaining Wall Code

Compare homeowner reviews from 6 top san francisco retaining wall install services.
San francisco retaining wall code. Retaining wall installations can look nice from the front but if you don t pay serious attention to what goes on behind and below you could be in for a nasty surprise. Wall building codes encourage uniformity. 2016 san francisco building code ab 032 b. 01 01 2014 page 1 of 5.
These ordinances have been incorporated into the 2016 san francisco building code. Of a retaining wall is measured from grade on the lower side of the retaining wall to the top of the retaining wall exposed height e sdmc 113 0270 b 2. This definition also applies to freestanding pool walls. Hire the best retaining wall contractors in san francisco ca on homeadvisor.
San diego municipal code chapter 14 article 2 division 3 regulates the location and the height of the retaining walls in the required setbacks and in the visibility area as follows. The folsom municipal code adopts by reference the 1997 uniform building code ubc. Building a simple deck in san francisco can become a complex project due to san francisco department of building inspections abundant codes requirements and restriction. Retaining walls definitions a retaining wall is a wall designed to resist lateral earth and or fluid pressures including any surcharge in accordance with accepted engineering practice.
One of these requirements for this particular project is having to build a 1 hour fire wall since the deck abuts the property line. Ubc 106 2 item 5 states that. Top quality retaining wall installation in san francisco san mateo counties. This addendum includes piles pile caps spread footings line footings grade and tie beams and slabs on grade and underground utilities as applicable.
Building codes are one of those necessary evils that can be annoying at times but go a long way toward ensuring a safe house. San diego municipal code chapter 14 article 2 division 3 regulates the location and the height of the retaining walls in the required setbacks and in the visibility area as follows. Notice to tenants of dwelling unit merger or demolition ordinance 208 15 definition of vacant or abandoned buildings ordinance 14 16 conditional use required to remove any residential unit and mandatory legalization of illegal units in c 3 districts. Get quotes book instantly.
Cantilever retaining and basement walls not more than one story above grade may be included when clearly shown on the plans. Beauty that s more than skin deep. Of a retaining wall is measured from grade on the lower side of the retaining wall to the top of the retaining wall exposed height e sdmc 113 0270 b 2.